Range Operation
Condition for Fixed bed pyrolysis ( Rickshaw / bycycle ) tire:
Operating condition:
The fixed bed pyrolysis system is run under the following operating
conditions as presented in Table
| Flow gas |
Nitrogen |
| Gas flow rate (L/min) |
1.536x10-2 |
| Apparent residence time (sec) |
2.5<5 |
| Feed used per run (gm) |
500 |
| Feed size-Tire of bicycle/rickshaw (cm) |
10x1/2x1/4, 10x1x1/4, 10x2x1/4, 25x1x1/4, 25x2x1/4 |
| Feed size-Tire of truck (cm) |
10x2x1 |
|